Skip to main content

Table 5 Experimental result

From: Novel exterior cover design for radiant heat resistance of firefighting robots in large-scale petrochemical complex fires

Experiment symbol

Period for calculating the average temperature (s)

Outside air (°C)

The back surface of radiation heat shielding cloth (°C)

Simplified model of robot (°C)

Air in the simplified robot model: 5 points average temperature (°C)

Difference between the average air in the model and the outside air (°C)

Fig. number

(e1) (OD-N)

1370–1870

18.65

96.96

50.32

29.57

10.92

Figure 11

(e2) (CD-N)

2500–3000

18.25

95.78

52.37

34.96

16.71

Figure 11

(e3) (OW-N)

626–1126

18.37

69.42

34.47

24.74

6.38

Figure 12

2500–3000

17.56

100.93

49.11

27.06

9.49

Figure 12

(e4) (OD-1/30)

4100–5000

15.83

44.34

26.75

21.34

5.50

 

(e5) (OD-1/20)

2000–2500

17.21

38.16

24.46

21.53

4.323

 

(e6) (OD-1/60)

2000–2500

17.08

45.86

27.37

22.56

5.48

Figure 13

(e7) (OW-C)

2000–2500

17.00

20.31

19.53

20.12

3.12

Figure 14