Fig. 8From: A vacuum-driven rubber-band gripperRelationship between the internal air pressure and shrinkage ratio of the inner diameter of a rubber-band gripper. The gripper shrank rapidly when the inside air pressure decreased. The shrinkage ratio changed gently when the inside vacuum pressure exceeded − 10 kPa, and it became constant when the air pressure exceeded − 30 kPaBack to article page