Fig. 11From: Force sensor utilizing stiffness change of shape-memory polymer based on temperatureRelationship between applied force and strain on steel plate (second prototype): a h T = 0.05 mm, b h T = 0.1 mm, c h T = 0.3 mm. The alternate long and short dash lines show linear approximation. The linear approximation formulae are also shownBack to article page