Skip to main content
Fig. 7 | ROBOMECH Journal

Fig. 7

From: Unsupervised learning approach to automation of hammering test using topological information

Fig. 7

ROC curve for the delamination type blocks. Higher values of delamination inclination means deeper defects and therefore less audible, recordable sounds. This causes a drop in performance in pair with the inclinaison of the delamination. However, considering the still high efficiency for delaminations up to 45° and knowing that the vast majority of field-found delamination falls in this range, our proposed method can be considered satisfying